Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Inst Mech Eng H ; 221(5): 475-88, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17822150

RESUMO

This investigation explores a new cartilage repair technique that uses a novel method to secure a non-woven multifilamentous scaffold in the defect site after microfracture. The hypothesis is that a scaffold provides a larger surface area for attachment and proliferation of the mesenchymal stem cells that migrate from the bone marrow. Two in-vivo studies were undertaken in an ovine model. The first study, which lasted for 8 weeks, aimed to compare the new technique with microfracture. Chondral defects, 7 mm in diameter, were created in both femoral medial condyles of five ewes. One defect was treated with the new technique while the contralateral knee was treated with microfracture alone. The results revealed that the quantity of repair tissue was significantly greater in the defects treated with the new system. The second study had two time points, 3 and 6 months, and used 13 ewes. In this study, both defects were treated with the new technique but one received additional subchondral drilling in order to stimulate extra tissue growth. The majority of the implants had good tissue induction, filling 50-100 per cent of the defect volume, while the compressive modulus of the repairs was in the range of 40-70 per cent of that for the surrounding cartilage. In addition, hyaline-like cartilage was seen in all the repairs which had the additional drilling of the subchondral bone.


Assuntos
Fraturas de Cartilagem/fisiopatologia , Fraturas de Cartilagem/cirurgia , Regeneração Tecidual Guiada/instrumentação , Próteses e Implantes , Engenharia Tecidual/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Fraturas de Cartilagem/patologia , Regeneração Tecidual Guiada/métodos , Ovinos , Engenharia Tecidual/métodos , Resultado do Tratamento
2.
J Mater Sci Mater Med ; 16(8): 775-81, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15965749

RESUMO

The work presented details the results of an investigation into the feasibility of using Selective Laser Sintering (SLS) to directly produce customised bioceramic implants. The materials used were bioactive in nature and included a glass-ceramic and a combination of hydroxyapatite and phosphate glass. The glass-ceramic was selected from the range of apatite-mullite materials in the SiO2.Al2O3.CaO.CaF2.P2O5 series, due to their potentially suitable biological and mechanical properties. The hydroxyapatite and phosphate glass combination was chosen to allow an alternative production approach to be investigated. The viability of using both these materials with the SLS process was assessed and the process route and resulting material properties characterised using a variety of techniques including Differential Thermal Analysis (DTA), X-ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The results obtained indicate that it was possible to produce multiple layer components from both materials using the SLS process. The glass-ceramic materials could only be processed at very low scan speeds and powers, yielding relatively brittle components. It was though possible to produce parts from the hydroxyapatite and phosphate glass combination across a much wider range of parameters, producing parts which had a greater potential for possible implant production.


Assuntos
Silicatos de Alumínio/química , Apatitas/química , Substitutos Ósseos/química , Durapatita/química , Vidro/química , Lasers , Fosfatos/química , Silicatos de Alumínio/análise , Silicatos de Alumínio/efeitos da radiação , Apatitas/análise , Apatitas/efeitos da radiação , Materiais Biocompatíveis/análise , Materiais Biocompatíveis/química , Materiais Biocompatíveis/efeitos da radiação , Substitutos Ósseos/análise , Substitutos Ósseos/efeitos da radiação , Durapatita/análise , Durapatita/efeitos da radiação , Estudos de Viabilidade , Vidro/análise , Vidro/efeitos da radiação , Temperatura Alta , Teste de Materiais , Tamanho da Partícula , Fosfatos/análise , Fosfatos/efeitos da radiação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...